Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Int. j. cardiovasc. sci. (Impr.) ; 36: e20210040, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1421770

ABSTRACT

Abstract Takayasu arteritis (TA) is a rare type of vasculitis that affects mainly the aorta and its major branches. It is highly similar to giant cell arteritis (GCA), and differentiation between them may not be achieved even by histological examination. Arterial hypertension is typical of TA and is caused by stenosis of the renal arteries. Here we report the case of a 59-year-old woman, with a history of dyslipidemia and anemia, seen in the Internal Medicine department for resistant hypertension. Evaluation of secondary causes led to stenosis of the renal arteries. Assessment of target organ involvement was performed by computed tomography angiograph which revealed ectasia of the aortic arch and ascending aorta, tortuous course of the brachiocephalic trunk and the proximal portion of the right common carotid artery; positron-emission tomography which showed diffuse increased uptake in the ascending aorta, compatible with large vessels vasculitis. The patient was submitted to aortic valve replacement with a biological prosthesis combined with myocardial revascularization (Bentall-De Bono procedure). Aortic biopsy specimens showed anatomical and pathological features of GCA and TA. Due to persistently uncontrolled hypertension, prednisone 60 mg was initiated,with significant improvement in patient's condition.

3.
Arq. bras. cardiol ; 115(4): 680-687, out. 2020. graf
Article in Portuguese | SES-SP, LILACS | ID: biblio-1131356

ABSTRACT

Resumo Fundamento O implante valvar aórtico percutâneo (TAVR, do inglês Transcatheter Aortic Valve Replacement) reduz a mortalidade de pacientes portadores de estenose aórtica grave. O conhecimento da distribuição da pressão e tensão de cisalhamento na parede aórtica pode ajudar na identificação de regiões críticas, onde o processo de remodelamento aórtico pode ocorrer. Neste trabalho é apresentado um estudo de simulação computacional da influência do posicionamento do orifício valvar protético na hemodinâmica na raiz de aorta e segmento ascendente. Objetivos A presente análise apresenta um estudo da variação do padrão de fluxo devido a alterações no ângulo do orifício valvar. Métodos Um modelo tridimensional foi gerado a partir do exame de angiotomografia computadorizada da aorta de um paciente que foi submetido ao procedimento de TAVR. Diferentes vazões de fluxo foram impostas através do orifício valvar. Resultados Pequenas variações no ângulo de inclinação causaram mudanças no padrão de fluxo, com deslocamento na posição dos vórtices, na distribuição de pressão e no local de alta tensão cisalhante na parede aórtica. Conclusão Essas características hemodinâmicas podem ser importantes no processo de remodelamento aórtico e distribuição de tensão, além de auxiliar, em um futuro próximo, a otimização do posicionamento da prótese valvar percutânea. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Backgroud Transcatheter aortic valve replacement (TAVR) can reduce mortality among patients with aortic stenosis. Knowledge of pressure distribution and shear stress at the aortic wall may help identify critical regions, where aortic remodeling process may occur. Here a numerical simulation study of the influence of positioning of the prosthetic valve orifice on the flow field is presented. Objective The present analysis provides a perspective of great variance on flow behavior due only to angle changes. Methods A 3D model was generated from computed tomography angiography of a patient who had undergone a TAVR. Different mass flow rates were imposed at the inlet valve. Results Small variations of the tilt angle could modify the nature of the flow, displacing the position of the vortices, and altering the prerssure distribution and the location of high wall shear stress. Conclusion These hemodynamic features may be relevant in the aortic remodeling process and distribution of the stress mapping and could help, in the near future, the optimization of the percutaneous prosthesis implantation. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Subject(s)
Humans , Aortic Valve Stenosis/diagnostic imaging , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement/adverse effects , Aorta , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Computed Tomography Angiography , Hemodynamics
4.
Arq. bras. cardiol ; 113(4): 758-767, Oct. 2019. tab, graf
Article in English | SES-SP, LILACS, SESSP-IDPCPROD, SES-SP | ID: biblio-1038568

ABSTRACT

Abstract Coronary computed tomography angiography (CCTA) has gained a prominent role in the evaluation of coronary artery disease. However, its anatomical nature does not allow the evaluation of the functional repercussion of coronary obstructions. It has been made possible to evaluate Myocardial computed tomography perfusion (Myocardial CTP) recently, based on myocardial contrast changes related to coronary stenoses. Several studies have validated this technique against the anatomical reference method (cardiac catheterization) and other functional methods, including myocardial perfusion scintigraphy and fractional flow reserve. The Myocardial CTP is performed in conjunction with the CCTA, a combined analysis of anatomy and function. The stress phase (with assessment of myocardial perfusion) can be performed before or after the resting phase (assessment of resting perfusion and coronary arteries), and different acquisition parameters are proposed according to the protocol and type of equipment used. Stressors used are based on coronary vasodilation (e.g. dipyridamole, adenosine). Image interpretation, similar to other perfusion assessment methods, is based on the identification and quantification of myocardial perfusion defects. The integration of both perfusion and anatomical findings is fundamental for the examination interpretation algorithm, allowing to define if the stenoses identified are hemodynamically significant and may be related to myocardial ischemia.


Resumo A angiografia coronariana por tomografia computadorizada (ACTC) assumiu um papel de destaque na avaliação da doença arterial coronariana. Entretanto, sua natureza anatômica não permitia a avaliação da repercussão funcional das obstruções coronarianas. Recentemente, tornou-se possível a avaliação da perfusão miocárdica por tomografia computadorizada (PMTC), baseando-se nas alterações de contrastação miocárdicas relacionadas às estenoses coronarianas. Diversos estudos permitiram validar esta técnica perante o método anatômico de referência (cateterismo cardíaco) e outros métodos funcionais, incluindo cintilografia de perfusão miocárdica e a reserva de fluxo fracionada. A PMTC é realizada conjuntamente com a ACTC, em uma análise combinada de anatomia e função. A fase de estresse (com avaliação da perfusão miocárdica) pode ser realizada antes ou depois da fase de repouso (avaliação da perfusão de repouso e artérias coronárias), e diferentes parâmetros de aquisição são propostos conforme o protocolo e o tipo de equipamento utilizados. Os agentes estressores utilizados baseiam-se na vasodilatação coronariana (ex: dipiridamol, adenosina). A interpretação das imagens, semelhante a outros métodos de avaliação perfusional, baseia-se na identificação e quantificação de defeitos de perfusão miocárdicos. A integração dos achados perfusionais e anatômicos é parte fundamental do algoritmo de interpretação do exame, permitindo definir se as estenoses identificadas são hemodinamicamente significativas, podendo se relacionar com isquemia miocárdica.


Subject(s)
Humans , Coronary Angiography/methods , Myocardial Perfusion Imaging/methods , Computed Tomography Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Angiography/standards , Myocardial Ischemia/diagnostic imaging , Contrast Media , Myocardial Perfusion Imaging/standards , Computed Tomography Angiography/standards
SELECTION OF CITATIONS
SEARCH DETAIL